Whether gloveboxes, inert gas cleaning, thin film technology, isolators or customised system solutions in clean environments, MBRAUN has the right solution for you. With over 45 years of experience, MBRAUN has the expertise to provide high quality custom solutions for controlled environments. We continue to develop world-class core technologies and then customise them to an application to create the most efficient clean environments based on our intimate knowledge of the many markets we serve.
Whether it's about exhibitions, roadshows or other events, about product innovations, the latest trends in the industry or interesting solutions from our users: You will find information on these topics from us on almost all channels, around the clock.
Hitachi Uv Solutions Software 11
Cell migration, the movement of cells from one location to another, is a critical component of both normal and abnormal biological processes. The migration of fluorescently labeled cells from one area of a microplate well to another can be monitored using a cellular imaging system. Automated analysis software calculates the amount of cell migration in each well.
THE MASKLESS ALIGNER FOR VOLUME PRODUCTIONThe MLA300 is the industrial production version of the Maskless Aligner, which already has become a standard in Research & Development applications, rapid prototyping, and low-to mid-volume production. The MLA300 achieves high resolutions of 2 µm lines and spaces at the high throughput and high availability expected in production. It features full automation with wafer robot and load ports, and software specifically designed for the production environment to offer a simplified automated workflow.
The CMT-SR5000 is a high precision Four Point Prone system equipped to measure the Sheet Resistance and Resistivity of Silicon Wafer. This system is designed for easy operation by a personal computer with exclusive software, and this software has functions for various data analyses mapping and so on.
The primary applications for the instrument are UV-Vis measurements for nucleic acid and protein quantification, kinetic studies and microbial cell quantification. The intuitive interface helps users quickly create custom methods that may be defined and saved in password-protected accounts. Results are automatically stored and easily exported to e-mail, USB, network folders, network printers, LIMS, USB drives and label printers. IQ/OQ documentation and performance verification software is available to help achieve compliance in GLP/GMP environments.
UV/VIS: Hitachi U-2810 with UV solutions software. & UZ910 with UV Solutions Software FTIR: Perkin Elmer Spectrum One with Assure ID & Spectrum 100 with Assure ID. Balances: Mettler AT201 Analytical balance, Mettler MX5 Micro balance, XP205 Analytical balance, AX205 Analytical balanceDSC: Mettler DSCI Star System
Basic manually controlled upright microscope for fluorescent or brightfield samples mounted on slides. Mercury HBO white light lamp for fluorescence excitation and DAPI, GFP, and Texas Red filter cubes. The system also has a Green/Red (dual band) filter cube for simultaneous two channel visual observation. Additional CFP, YFP, and Cy5 filter cubes are available for this microscope if needed. Objectives: 1.25x dry, 5x dry, 10x dry, 20x dry, 40x dry, 63x water. The microscope is equipped with a QImaging Retiga 4000R monochrome camera for fluorescent pseudo-color or brightfield monochrome imaging. This microscope is not equipped for imaging color brightfield stains. Images are acquired using QCapture Pro 7 software.Location: CTAC Imaging Suite (MBI LG-164)
Laser-scanning confocal (LSCM), multiphoton (MP), and STORM (super-resolution) inverted microscope for fluorescent samples. Available Tokai-Hit stage top incubator with active CO2 and temperature regulation, and passive humidity, for imaging live cells in a 35mm dish or a chambered coverglass. Motorized XY stage movement for multi-point time-lapse imaging or tile-mapping (AKA mosaic or stitching). Galvo and resonant scanning. Software: Nikon NIS-Elements v5.0 on a Windows 7 workstation. (This software is also available (with the optional Deconvolution module) on our separate Windows 7 Analysis Workstation.)
Inverted widefield microscope with motorized XY stage for fluorescent or brightfield samples. Available Tokai-Hit stage top incubator with active CO2 and temperature regulation, and passive humidity, for imaging live cells in a 35mm dish or a chambered coverglass. Motorized XY stage movement for multi-point time-lapse or tile-mapping (AKA mosaic or stitching). Objectives: 10x dry, 20x dry, 40x dry, and 60x water. Multi-line LED lamp for fluorescent excitation. Fluorescent filter sets: DAPI, GFP/FITC, TRITC, Texas Red, and CY5. Phase Contrast optics for 10x and 20x. DIC (Nomarski) optics for 40x and 60x. Two cameras: Andor Zyla sCMOS 11 bit monochrome for fluorescence, and a Nikon DS-Fi2 color camera for stained brightfield samples. Software: Nikon NIS-Elements v4.51 on a Windows 7 workstation. (This software is also available (with the optional Deconvolution module) on our separate Windows 7 Analysis Workstation.
Basic manually controlled inverted microscope for fluorescent or brightfield samples mounted on slides, or in dishes/plates. Mercury metal-halide white light lamp for fluorescence excitation and DAPI, GFP, TRITC filter cubes. An additional Cy5 filter cube may be installed if needed. Objectives: 4x dry, 10x dry, 20x dry LWD, 40x dry, 60x water. The microscope is equipped with a QImaging Retiga 4000R monochrome camera for fluorescent pseudo-color or brightfield monochrome imaging. This system also has an optional LCD color module which allows it to capture images of color stained samples in brightfield. Images are acquired using QCapture Pro 7 software.
Spinning disk confocal inverted microscope with motorized XY stage for fluorescence labeled samples. Available Tokai-Hit stage top incubator with active CO2 and temperature regulation, and passive humidity, for imaging live cells in a 35mm dish. Motorized XY stage movement for tile-mapping (AKA mosaic or stitching) and Z-drive for basic confocal Z-stack imaging. Objectives: 10x dry, 20x dry, 20x dry LWD, 40x dry, and 60x water. LED lamp for fluorescent excitation. Fluorescent filter sets: DAPI, GFP/FITC, TRITC, Texas Red, and CY5. Camera: Hamamatsu ORCA Flash 4.0 LT+ (16 bit monochrome). Software: Olympus CellSensPlease Note: These systems are now using a new software platform (Olympus CellSens). Users who previously operated the system will need to undergo an orientation/re-training before they will be able to use the system again. 2ff7e9595c
Comments